ISO 4064-2:2014|OIML R 49-2:2013 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2014|OIML R 49-1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that ISO 4064-2:2014|OIML R 49-2:2013, ISO 4064-1:2014|OIML R 49-1:2013 and ISO 4064-3:2014|OIML R 49-3:2013 are used in accordance with the rules of the system. ISO 4064-2:2014|OIML R 49-2:2013 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of ISO 4064-2:2014|OIML R 49-2:2013 also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.
Tämän julkaisun valmistelusta Suomessa vastaa Metalliteollisuuden Standardisointiyhdistys ry, puh. 09 19 231 (vaihde).
Sisällysluettelo
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Reference conditions
5 Symbols, units and equations
6 External examination
6.1 General
6.2 Object of the examination
6.3 Preparation
6.4 Examination procedures
7 Performance tests for all water meters
7.1 General
7.2 Required conditions for all tests
7.3 Static pressure test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.10)
7.4 Determination of intrinsic errors (of indication) (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.3)
7.5 Water temperature test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.8)
7.6 Overload water temperature test (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.5)
7.7 Water pressure test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.8)
7.8 Reverse flow test (ISO 4064-1:2014|OIML R 49‑1:2013, 4.2.7)
7.9 Pressure loss test (ISO 4064-1:2014|OIML R 49‑1:2013, 6.5)
7.10 Flow disturbance tests (ISO 4064-1:2014|OIML R 49‑1:2013, 6.3.4)
7.11 Durability tests (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.6)
7.12 Magnetic field testing
7.13 Tests on ancillary devices of a water meter
7.14 Environmental testing
8 Performance tests related to influence factors and disturbances
8.1 General requirements (ISO 4064-1:2014|OIML R 49‑1:2013, A.1)
8.2 Dry heat (non-condensing) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.3 Cold (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.4 Damp heat, cyclic (condensing) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.5 Power supply variation (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.6 Vibration (random) (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.7 Mechanical shock (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.8 AC mains voltage dips, short interruptions and voltage variations (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.9 Bursts on signal lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.10 Bursts (transients) on AC and DC mains (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.11 Electrostatic discharge (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.12 Radiated electromagnetic fields (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.13 Conducted electromagnetic fields (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.14 Surges on signal, data and control lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.15 Surges on AC and DC mains power lines (ISO 4064-1:2014|OIML R 49‑1:2013, A.5)
8.16 Static magnetic field (ISO 4064-1:2014|OIML R 49‑1:2013, 7.2.8)
8.17 Absence of flow test
9 Test program for type evaluation
9.1 Number of samples required
9.2 Performance test applicable to all water meters
9.3 Performance tests applicable to electronic water meters, mechanical water meters fitted with electronic devices, and their separable parts
9.4 Type evaluation of separable parts of a water meter
9.5 Families of water meters
10 Tests for initial verification
10.1 Initial verification of complete and combined water meters
10.2 Initial verification of separable parts of a water meter
11 Presentation of results
11.1 Object of the reports
11.2 Identification and test data to be included in records
Annex A Type examination and testing of checking facilities of electronic devices (normative)
Annex B Calculating the relative error (of indication) of a water meter (normative)
Annex C Installation requirements for flow disturbance tests (normative)
Annex D Type evaluation of a family of water meters (normative)
Annex E Examples of methods and components used for testing concentric water meters (informative)
Annex F Determining the density of water (informative)
Annex G Maximum uncertainties in the measurement of influence factors and disturbances (informative)
Annex H Pressure loss test pressure tappings, hole and slot details (informative)