This European Standard identifies material independent performance characteristics, except resistance to fire and smoke control characteristics, which are applicable to internal pedestrian doorsets. Fire resisting and/or smoke control characteristics for pedestrian doorsets and openable windows are covered by EN 16034. This European Standard applies to doorsets intended to be used internally for construction works as: - intended use a) in escape routes; - intended use b) for specific uses with specific requirements; - intended use c) for communication only. NOTE 1 These above intended uses can be combined, for example escape routes with specific requirements. For internal pedestrian doorsets with resistance to fire and /or smoke control characteristics, this standard should only apply in conjunction with EN 16034. Products covered by this European Standard are power operated hinged or manually operated internal pedestrian doorsets and screens with flush or panelled leaves, single or double leaf, which could be completed with: - related building hardware; - door closing devices; - integral fanlights; - adjacent parts that are contained within a single frame for inclusion in a single aperture. NOTE 2 Manually operated doors with door closing devices are not considered to be power operated doors. Products covered by this European Standard are not assessed for structural applications. This European Standard does not apply to: - industrial, commercial and garage doors and gates according to EN 13241; - external pedestrian doorsets according to EN 14351-1; - door leaves placed on the market as a single unit; - door frames placed on the market as a single unit; - power operated pedestrian doorsets, other than swing type, according to EN 16361. Doorsets can be placed on the market with their component (leaf and frame) separate when each of these components are clearly identified. This European Standard does not deal with any specific requirements on noise emitted from internal power operated hinged doorsets as their noise emission is not considered to be a relevant hazard.
Tämän julkaisun valmistelusta Suomessa vastaa Rakennustuoteteollisuus RTT ry, puh. 09 12 991 (vaihde).
EN 1026:2016 Windows and doors - Air permeability - Test method
EN 1121:2000 Doors - Behaviour between two different climates - Test method
EN 1125:2008 Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
EN 1026:2016 Windows and doors - Air permeability - Test method
EN 1121:2000 Doors - Behaviour between two different climates - Test method
EN 1125:2008 Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
EN 1154:1996 Building hardware - Controlled door closing devices - Requirements and test methods
EN 1191:2012 Windows and doors - Resistance to repeated opening and closing - Test method
EN 1192:1999 Doors - Classification of strength requirements
EN 12046-2:2000 Operating forces - Test method - Part 2: Doors
EN 12150-2:2004 Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard
EN 12207:2016 Windows and doors - Air permeability - Classification
EN 12217:2015 Doors - Operating forces - Requirements and classification
EN 12219:1999 Doors - Climatic influences - Requirements and classification
EN 12365-1:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification
EN 12365-2:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 2: Linear compression force test methods
EN 12365-3:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 3: Deflection recovery test method
EN 12365-4:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method
EN 12400:2002 Windows and pedestrian doors - Mechanical durability - Requirements and classification
EN 12519:2018 Windows and pedestrian doors - Terminology
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass
EN 13049:2003 Windows - Soft and heavy body impact - Test method, safety requirements and classification
EN 13123-1:2001 Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube
EN 13124-1:2001 Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube
EN 13141-1:2019 Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 1: Externally and internally mounted air transfer devices
EN 13141-2:2010 Ventilation for buildings - Performance testing of components/products for residential ventilation - Part 2: Exhaust and supply air terminal devices
EN 13238:2010 Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates
EN 13501-1:2018 Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests
EN 13637:2015 Building hardware - Electrically controlled exit systems for use on escape routes - Requirements and test methods
EN 14179-2:2005 Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
EN 14449:2005 Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard
EN 1522:1998 Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification
EN 1523:1998 Windows, doors, shutters and blinds - Bullet resistance - Test method
EN 16005:2012 Power operated pedestrian doorsets - Safety in use - Requirements and test methods
EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
EN 1627:2011+A1 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification
EN 1627:2021 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification
EN 1628:2011+A1:2015 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading
EN 1628:2021 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading
EN 1629:2011+A1:2015 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
EN 1629:2021 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
EN 1630:2011+A1:2015 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
EN 1630:2021 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
EN 179:2008 Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods
EN 1935:2002 Building hardware - Single-axis hinges - Requirements and test methods
EN 947:1998 Hinged or pivoted doors - Determination of the resistance to vertical load
EN 948:1999 Hinged or pivoted doors - Determination of the resistance to static torsion
EN 949:1998 Windows and curtain walling, doors, blinds and shutters - Determination of the resistance to soft and heavy body impact for doors
EN 950:1999 Door leaves - Determination of the resistance to hard body impact
EN ISO 10077-1:2006 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2006)
EN ISO 10077-2:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017)
EN ISO 10140-1:2016 Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2016)
EN ISO 10140-1:2021 Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2021)
EN ISO 10140-2:2010 Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010)
EN ISO 10140-2:2021 Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2021)
EN ISO 12567-1:2010 Thermal performance of windows and doors - Determination of thermal transmittance by the hot-box method - Part 1: Complete windows and doors (ISO 12567-1:2010)
EN ISO 717-1:2020 Acoustics - Rating of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation (ISO 717-1:2020)