Lyhenteet

- A / A +

Takaisin

SFS-EN 1090-5:2017:en

Execution of steel structures and aluminium structures. Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications

Tuote ladattavissa heti Toimitusaika on noin 1 - 2 työpäivää Toimitusaika on 3 - 5 työpäivää.
Soveltamisala
Suomenkielistä soveltamisalaa ei ole saatavissa.

This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.
Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.
Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas.
This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.
A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.
Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
NOTE The structures covered in this standard can be for example
- single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;
- single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or
- suspended ceilings for interior fitting.


Tämän julkaisun valmistelusta Suomessa vastaa Metalliteollisuuden Standardisointiyhdistys ry, puh. 09 19 231 (vaihde).
Sidokset
Velvoittavat viittaukset
CEN/TS 1187:2012 Test methods for external fire exposure to roofs
EN 10204:2004 Metallic products - Types of inspection documents
EN 1090-1:2009+A1:2011 Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components
Vahvistuspäivä
31.03.2017
Julkaisupäivä
04.04.2017
Painos
1
Sivumäärä
59
Julkaisun kieli
englanti
Lisätiedot
Lisätietoja eurokoodeista www.eurocodes.fi.