This European Standard applies to low smoke halogen-free, flexible, single-core power cables with cross-linked insulation and sheath. In particular for use at the direct current (d.c.) side of photovoltaic systems, with a nominal d.c. voltage of 1,5 kV between conductors and between conductor and earth. The cables are suitable to be used with Class II equipment. The cables are designed to operate at a normal maximum conductor temperature of 90 °C, but for a maximum of 20 000 hours a max. conductor temperature of 120 °C at a max. ambient temperature of 90 °C is permitted. NOTE The expected period of use under normal usage conditions as specified in this standard is at least 25 years.
Tämän julkaisun valmistelusta Suomessa vastaa SESKO ry, puh. 050 571 6048.
EN 50289-4-17:2015 Communication cables - Specifications for test methods - Part 4-17: Test methods for UV resistance evaluation of the sheath of electrical and optical fibre cable
EN 50395:2005 Electrical test methods for low voltage energy cables
EN 50396:2005 Non electrical test methods for low voltage energy cables
EN 50289-4-17:2015 Communication cables - Specifications for test methods - Part 4-17: Test methods for UV resistance evaluation of the sheath of electrical and optical fibre cable
EN 50395:2005 Electrical test methods for low voltage energy cables
EN 50396:2005 Non electrical test methods for low voltage energy cables
EN 50525-1:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
EN 50565-1:2014 Energiakaapelit. Mitoitusjännitteiltään enintään 450/750 V (U0/U) pienjännitekaapelien käyttöohjeet. Osa 1: Yleiset ohjeet
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60216-1:2001 Electrical insulating materials - Properties of thermal endurance - Part 1: Ageing procedures and evaluation of test results
EN 60216-1:2013 Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results
EN 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
EN 60228:2005 Conductors of insulated cables
EN 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
EN 60811-401:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
EN 60811-403:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
EN 60811-404:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60811-503:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths
EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
EN 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
EN 60811-506:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
EN 60811-507:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
EN 61034-1:2005 Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
EN 61034-2:2005 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
EN 62230:2007 Electric cables - Spark-test method
HD 60364-5-52:2011 Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems
HD 60364-7-712:2016 Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems