SFS-EN ISO 15310:en

Fibre-reinforced plastic composites. Determination of the in-plane shear modulus by the plate twist method (ISO 15310:1999)

Tuote ladattavissa heti Toimitusaika on noin 1 - 2 työpäivää Toimitusaika on 3 - 5 työpäivää.
Soveltamisala
Suomenkielistä soveltamisalaa ei ole saatavissa.

1.1 This International Standard specifies a method for determining the in-plane shear modulus (G12) of fibrereinforced plastic composites using a standard plate specimen. When applied to isotropic materials, the shear modulus measured is independent of direction.
1.2 The method is used to determine the shear modulus of the test specimens but not to determine the shear strength. It applies to a plate supported on two points on one diagonal and loaded on the other diagonal by the simultaneous movement of two loading points attached to a cross-beam.
1.3 The method is suitable for use with fibre-reinforced plastic composites with both thermoset and thermoplastic matrices.
Due to the shear deformation being applied under flexural conditions, for laminated materials with different fibre formats and/or different orientations, the layers of material must be well distributed across the section so that it is approximately “homogeneous” in the through-thickness direction.
The principal material axes, if present, must be orientated normal to the plate edges (see 3.8).
NOTE This method can be applied to unreinforced polymers and other materials (e.g. metals, ceramics and metal- or ceramic-matrix composites).
For material fabricated using unidirectional plies, the shear modulus obtained using a multidirectional specimen (i.e. 0°/90°/- 45°) is not the same as that obtained for unidirectional or cross-ply (0°/90°) material.
1.4 The method is performed using specimens which may be moulded to the chosen dimensions, machined from test plates or machined from flat areas of products.
1.5 The method specifies preferred dimensions for the specimen. Tests which are carried out on specimens of other dimensions, or on specimens which are prepared under different conditions, may produce results which are not comparable. Other factors, such as the speed of testing and the conditioning of the specimens, can influence the results. Consequently, when comparative data are required, these factors must be carefully controlled and recorded.
NOTE The stress-strain response in shear is very non-linear at higher strain levels. This test method determines the modulus within a low strain region and is not applicable to higher strains.

Tämän julkaisun valmistelusta Suomessa vastaa Kemesta ry, puh. 040 820 4888.
Sisällysluettelo
Tuoteryhmä(t)
Sidokset
Velvoittavat viittaukset
ISO 1268:1974 Plastics -- Preparation of glass fibre reinforced, resin bonded, low-pressure laminated plates or panels for test purposes
ISO 2602:1980 Statistical interpretation of test results -- Estimation of the mean -- Confidence interval
ISO 2818:1994 Plastics -- Preparation of test specimens by machining
Tekninen komitea
Vahvistuspäivä
13.02.2006
Julkaisupäivä
03.03.2006
Painos
1
Sivumäärä
14
Julkaisun kieli
englanti

Takaisin