Thermoplastics piping systems for non-pressure applications. Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings. Determination of the viscosity number and K-value (ISO 13229:2010)
Tuote ladattavissa hetiToimitusaika on noin 1 - 2 työpäivääToimitusaika on 3 - 5 työpäivää.
ISO 13229:2010 specifies a method for the determination of the viscosity number (also known as reduced viscosity) and K-value of an unplasticized poly(vinyl chloride) (PVC) resin derived from a pipe, fitting or compound. In ISO 13229:2010, only the method for isolation (or separation) of the PVC resin is detailed.
Tämän julkaisun valmistelusta Suomessa vastaa Muoviteollisuus ry, puh. 09 172 841 (vaihde).
Sisällysluettelo
Foreword
1 Scope
2 Normative references
3 Principle
4 Reagents for isolation or separation of the PVC resin
5 Apparatus for isolation or separation of the PVC resin
6 Procedure
6.1 Isolation or separation of the PVC resin
6.2 Determination of the viscosity number
7 Calculation of K-value
8 Accuracy
9 Test report
Annex A Relationship between K-value and viscosity number for PVC resin (informative)
ISO 1628-2:1998 Plastics -- Determination of the viscosity of polymers in dilute solution using capillary viscometers -- Part 2: Poly(vinyl chloride) resins