Plastics. Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics. Part 2: Method for materials sensitive to time-temperature history and/or moisture (ISO 1133-2:2011)
Tuote ladattavissa hetiToimitusaika on noin 1 - 2 työpäivääToimitusaika on 3 - 5 työpäivää.
ISO 1133-2:2011 specifies a procedure for the determination of the melt volume-flow rate (MVR) and melt mass-flow rate (MFR) of thermoplastic materials that exhibit a high rheological sensitivity to the time-temperature history experienced by the sample during the test and/or to moisture. It is possible that this method will not be appropriate for materials whose rheological behaviour is extremely affected during testing. MFR values can be determined by calculation from MVR measurements provided the melt density at the test temperature and pressure is known, or by measurement using a cutting device provided that the accuracy of the measurement is at least the same as that of the MVR measurement. The primary difference between ISO 1133-2:2011 and ISO 1133-1 is that ISO 1133-2:2011 specifies tighter tolerances on the temperature in the cylinder and on the time duration over which the material is subjected to that temperature. Thus the time-temperature history of the material is more tightly controlled and consequently, for materials that are likely to be affected by exposure to elevated temperatures, the variability of test results is reduced compared with whether the specifications of ISO 1133-1 were used. ISO 1133-2:2011 also provides information for preparation and handling of moisture sensitive materials that again are critical to obtaining repeatable, reproducible and accurate data. The test conditions for measurement of the MVR and MFR are often specified in the material standard. However, for those materials where there are no test conditions specified in the material standard, it is necessary for the test conditions to be agreed between the interested parties
Tämän julkaisun valmistelusta Suomessa vastaa Kemesta ry, puh. 040 820 4888.
Sisällysluettelo
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
5.1 Extrusion plastometer
5.2 Accessory equipment
6 Test sample
6.1 Sample form
6.2 Sample pre-treatment and storage
7 Temperature verification, cleaning and maintenance of the apparatus
7.1 Verification of the temperature-control system
7.2 Cleaning the apparatus
7.3 Vertical alignment of the instrument
8 Procedural set-up
8.1 General
8.2 Selection of temperature and load
8.3 Cleaning
8.4 Selection of sample mass and charging the cylinder
9 Procedure
9.1 Selection of temperature and load
9.2 Minimum piston displacement distance
9.3 Timer device
9.4 Preparation for the test
9.5 Measurement
9.6 Expression of results
10 Flow rate ratio (FRR)
11 Precision
12 Test report
Annex A Verification of temperature in the cylinder (informative)
Annex B Repeated MVR determinations on different materials carried out in line with this part of ISO 1133 (informative)
ISO 1133-1:2011 Plastics -- Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics -- Part 1: Standard method
ISO 15512:2008 Plastics -- Determination of water content
ISO 472:1999 Plastics -- Vocabulary
ISO 1133-1:2011 Plastics -- Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics -- Part 1: Standard method
ISO 15512:2008 Plastics -- Determination of water content
ISO 472:1999 Plastics -- Vocabulary