ISO 10580:2010 specifies a general laboratory test method for determination of the area-specific emission rate of volatile organic compounds (VOC) and/or the vapour-phase VOC concentration under defined climate conditions. ISO 10580:2010 describes emission test chambers used for the determination of the emission of volatile organic compounds from resilient, textile and laminate floor coverings.
Tämän julkaisun valmistelusta Suomessa vastaa Muoviteollisuus ry, puh. 09 172 841 (vaihde).
Sisällysluettelo
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Apparatus
5.1 Emission test chamber system
6 Sampling the product and transport and storage of sample
6.1 Sampling
6.2 Sample packaging and transport
6.3 Sample description
6.4 Storage of the sample prior to starting the testing
7 Preparation of test specimens
7.1 Specimens from rolls
7.2 Samples of rigid products such as tiles and planks
8 Emission test chamber system
8.1 General
8.2 Emission test chamber description
8.3 Air supply and mixing facilities
8.4 Airtightness
8.5 Air sampling manifold
8.6 Recovery and sink effects
9 Test conditions
9.1 Temperature and relative air humidity
9.2 Temperature and relative-air-humidity control systems
9.3 Supply-air quality and background concentration
9.4 Air velocity
9.5 Loading factor and air change rate
9.6 Air change rate in the emission test chamber
9.7 Emission test chamber airtightness
9.8 Efficiency of the internal emission-test-chamber air mixing
10 Preparation of emission test chamber
11 Test procedure
11.1 Test conditions in the emission test chamber
11.2 Background concentrations
11.3 Test specimen location in the emission test chamber
11.4 Time for measurements of test-chamber air concentration
11.5 Air sampling
12 Analysis of the air samples
12.1 Analysis of VOC
12.2 Analysis of formaldehyde and carbonyl compounds
13 Calculation of vapour concentrations and area-specific emission rates
14 Performance characteristics
15 Test report
Annex A General description of an emission test chamber (informative)
ASTM D 5197:2009 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
ISO 16000-11:2006 Indoor air -- Part 11: Determination of the emission of volatile organic compounds from building products and furnishing -- Sampling, storage of samples and preparation of test specimens
ISO 16000-3:2011 Indoor air -- Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air -- Active sampling method
ASTM D 5197:2009 Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
ISO 16000-11:2006 Indoor air -- Part 11: Determination of the emission of volatile organic compounds from building products and furnishing -- Sampling, storage of samples and preparation of test specimens
ISO 16000-3:2011 Indoor air -- Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air -- Active sampling method
ISO 16000-6:2004 Indoor air -- Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID
ISO 16000-9:2006 Indoor air -- Part 9: Determination of the emission of volatile organic compounds from building products and furnishing -- Emission test chamber method
ISO 16017-1:2000 Indoor, ambient and workplace air -- Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography -- Part 1: Pumped sampling