Ultrasonics - Field characterization - Test methods for the determination of thermal and mechanical indices related to medical diagnostic ultrasonic fields
Tuote ladattavissa hetiToimitusaika on noin 1 - 2 työpäivääToimitusaika on noin 3 - 5 työpäivää
IEC 62359:2010 is applicable to medical diagnostic ultrasound fields. It establishes: - parameters related to thermal and non-thermal exposure aspects of diagnostic ultrasonic fields; - methods for the determination of an exposure parameter relating to temperature rise in theoretical tissue-equivalent models, resulting from absorption of ultrasound; - methods for the determination of an exposure parameter appropriate to certain non-thermal effects. This second edition cancels and replaces the first edition, published in 2005. It constitutes a technical revision. Major changes with respect to the previous edition include the following: - The methods of determination set out in the first edition of this standard were based on those contained in the American standard for Real-Time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment (ODS) and were intended to yield identical results. While this second edition also follows the ODS in principal and uses the same basic formulae and assumptions (see Annex A), it contains a few significant modifications which deviate from the ODS. - One of the primary issues dealt with in preparing this second edition of IEC 62359 was 'missing' TI equations. In Edition 1 there were not enough equations to make complete 'at-surface' and 'below-surface' summations for TIS and TIB in combined-operating modes. Thus major changes with respect to the previous edition are related to the introduction of new calculations of thermal indices to take into account both 'at-surface' and 'below-surface' thermal effects.
Tämän julkaisun valmistelusta Suomessa vastaa SESKO ry, puh. 050 571 6048.
EN 60601-2-37:2008 Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
EN 61157:2007 Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment
EN 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
EN 60601-2-37:2008 Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
EN 61157:2007 Standard means for the reporting of the acoustic output of medical diagnostic ultrasonic equipment
EN 61161:2013 Ultrasonics - Power measurement - Radiation force balances and performance requirements
EN 61828:2001 Ultrasonics - Focusing transducers - Definitions and measurement methods for the transmitted fields
EN 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz
EN 62127-2:2007 Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz
EN 62127-3:2007 Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz
EN IEC 61828:2021 Ultrasonics - Transducers - Definitions and measurement methods regarding focusing for the transmitted fields
EN IEC 62127-1:2022 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
EN IEC 62127-3:2023 Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields