IEC 60127-7:2015(E) covers requirements for miniature fuse-links for special applications. This part of IEC 60127 is applicable to fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This part of IEC 60127 applies in addition to the requirements of IEC 60127-1. Miniature fuse-links for special applications are not intended to be replaced by the end-user of an electrical/electronic appliance. The object of this part of IEC 60127 is to establish uniform test methods for miniature fuse-links for special applications, so as to allow verification of the values (for example melting time and breaking capacity values) specified by the manufacturer. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition:
- defining a test board for surface mount fuse-links, Figure 2;
- defining test schedules for homogenous series.
This publication is to be read in conjunction with IEC 60127-1:2006. Keywords: fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA.
Tämän julkaisun valmistelusta Suomessa vastaa SESKO ry, puh. 050 571 6048.
EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
EN 60127-1:2006 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links
EN 60127-1:2006/A1:2011 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links
EN 60068-2-21:2006 Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices
EN 60127-1:2006 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links
EN 60127-1:2006/A1:2011 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links
EN 60127-1:2006/A2:2015 Miniature fuses - Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links
EN 60127-4:2005 Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
EN 60127-4:2005/A1:2009 Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
EN 60127-4:2005/A2:2013 Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
EN 60127-6:2014 Miniature fuses - Part 6: Fuse-holders for miniature fuse-links
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60695-2-12:2010 Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials
EN 60695-2-12:2010/A1:2014 Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials
EN 60695-2-13:2010 Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials
EN 60695-2-13:2010/A1:2014 Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials
EN 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
EN 61249-2-7:2002 Materials for printed boards and other interconnecting structures - Part 2-7: Reinforced base materials, clad and unclad - Epoxide woven E-glass laminated sheet of defined flammability (vertical burning test), copper-clad
ISO 3:1973 Preferred numbers -- Series of preferred numbers