Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables screened and thin wall sheathed
Tuote ladattavissa hetiToimitusaika on noin 1 - 2 työpäivääToimitusaika on noin 3 - 5 työpäivää
This document specifies requirements for, and constructions and dimensions of, multicore cables, rated voltage U0/ U = 300/500 V, of the following type: Screened (0,5 mm2 to 2,5 mm2, number of cores from 1 to 8). All cables have stranded tinned copper conductors, and thin wall thickness, halogen-free, insulation and sheath. They are for use in railway rolling stock as fixed wiring or wiring where limited flexing in operation is encountered. These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 110 °C/20 000 h temperature index. If the customer were to require lifetime predictions this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions, the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50306 3:2020 is expected to be used in conjunction with EN 50306 1:2020, General Requirements, and EN 50306 2:2020, Single core cables.
Tämän julkaisun valmistelusta Suomessa vastaa SESKO ry, puh. 050 571 6048.
EN 45545-1:2013 Railway applications - Fire protection on railway vehicles - Part 1: General
EN 50305:2020 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50306-1:2020 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 45545-1:2013 Railway applications - Fire protection on railway vehicles - Part 1: General
EN 50305:2020 Railway applications - Railway rolling stock cables having special fire performance - Test methods
EN 50306-1:2020 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
EN 50306-2:2020 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
EN 60811-1-1:1995 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-1-1:1995/A1:2001 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-1-2:1995 Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
EN 60811-1-2:1995/A2:2000 Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
EN 60811-1-3:1995/A1:2001 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
EN 60811-1-4:1995/A2:2001 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
EN 61034-2:2005 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
EN 62230:2007 Electric cables - Spark-test method